| BIONICS INDUSTRIAL SAPHIRE-5000 SERIES |
|
| INTRODUCTION |
|
Bionics Advanced Filtration System Pvt. Ltd. presents a small and medium capacity Industrial RO plant model Saphire 5000 series. This Bionics® Industrial RO System can be customized for 50 to 2000 Liter Per Hour capacity. Depending upon customer requirement Bionics Advanced Filtration Systems Pvt. Ltd. is able to install Industrial RO System with capacities 50, 100, 250, 500, 1000, 2000, 5000 and up to 10000 Liter Per Hour (LPH). We are Industrial reverse osmosis plants manufacturer of small & medium capacity since 2001. This system is designed, developed and programmed for the long and dependable services. Our saphire series Industrial reverse osmosis water purifiers are ideal for small and medium industrial organizations, which require an output ranging from 100 gallons per day to 5000 gallon per day. Our Industrial RO plant gives a unique high quality output of TDS range between 10 – 50 ppm, assuming an input water have TDS levels under 600 ppm (Standard)
(Customized Module for higher TDS levels are also designed)
So as to produce the output water which meets the desired standards of water quality as per FDA and NSF, our Industrial Reverse Osmosis plant integrate various stages or consoles, which are integrated and synchronized to provide the desired results. The unique feature that helps us stand out from the regular Industrial reverse osmosis plants manufacturer, is that our pre conditioning consoles, RO Treatment consoles, Post Filtration Treatment Consoles, can all be purchased either stand alone or fully integrated systems, giving a unique advantage to the industrial units already using Industrial Reverse Osmosis plants, who want to change their existing system but still have some consoles of the existing units working fine or in good condition. So they can opt/choose not to purchase the existing consoles in good conditions. Our system engineers ensure complete integration of our industrial RO plants, with existing modules. |
|
Pre Conditioning Module Of Industrial Reverse Osmosis Plants |
|
This module is a very critical and important to all industrial reverse osmosis water plantr’s safe operation. Improperly treated water can spell doom to highly expensive RO module and various other components of your system and would surely compromise with the quality of the output water.
Our engineers design this module after performing the complete analysis of the feed water scenario of your site. This analysis determines the elements, hardness and contaminants present in the water and helps us determine the extent of pre conditioning required and configure the all important module of our industrial reverse osmosis water purifiers.
The standard pre conditioning module of our system comprises of:
- High efficiency multi media sediment filters, so as to remove sediments and suspended particulates from water.
- A water softener module is incorporated with the sediment filter to remove the excess presence of minerals in feed water.
|
| Special Pre Conditioning Module for our Industrial Reverse Osmosis plants |
|
| Some special case scenarios, additional pre conditioning may be required , due to excessive presence of bacteria or other micro organisms or presence of iron in the feed water, which requires additional ultra violet treatment and specialize iron block filter. |
| RO Stage Module Of Industrial RO plants. |
|
Reverse Osmosis : (Process Explanation)
The process of reverse osmosis removes dissolved salts as well as organics. The process can be explained as the raw water I flown through the membrane by applying pressure, in the process a small percentage of the feed water permeates the membrane, the balance portion of water moves alongside the membrane without being filtered and moves along side the membrane without being filtered and moves out of the system. The stream which permeates through the membrane is the permeate, the second stream of water is called the concentrate because it carries the concentrated salts and other contaminants which are not able to permeate through or rejected through the membrane . Since the two streams of liquid flow side by side to each other this process is also called cross flow filtration process.
This process of water filtration ensures that the output water have 99.9% of pyrogens, viruses and bacteria rejection. |
|
Disinfection Module Of Industrial RO plants |
This is also a very important component of any industrial reverse osmosis plant, used in water processing. As per the standard procedure the output water which exits from our commercial RO water filter is stored in closed tanks, which results in stagnation of water and susceptible to biological contamination.
To over come this problem our system incorporates a combination of UV or Ozone or individual ultra violet treatment, as the situation demands. This treatment completely eliminates the possibility of contamination during storage. |
| Click for Technical Specification |
|